Model
|
RLK601
|
RLK602
|
RLK602D
|
RLK603
|
|
Specification
|
low sensitivity
|
Medium sensitivity
·
|
Medium sensitivity
Dual channel
|
high sensitivity
|
|
Application
|
Close range target detection (less than 5m)
|
Medium and long distance target detection (5m-50m)
|
Remote target detection (larger than 50m)
|
|
Detector
|
Uncooled MCT
|
2-4 stage TE cooled PVMCT
|
2-4 stage TE cooled PVMCT LN cooled or stirling cooled InSb或HgCdTe
|
|
Spectral Response
|
2-14μm
|
2-5μm or 2-14um
|
2-5μm or 2-14μm、
|
|
NEI
|
5E-3W/cm*cm
|
5E-8W/cm*cm
|
5E-12W/cm*cm
|
|
Dynamic Range
|
1E+5
|
1E+5
|
1E+5
|
|
Linearity
|
<5%
|
<3%
|
<2%
|
|
Stability
|
<5%
|
<3%
|
<2%
|
|
Entrance Diameter
|
42mm(1.0”)
|
42mm(1.65”)
|
152mm(6”)
|
|
Optical System
|
No
|
Transmissive infrared optical system
|
Cassegrain reflective infrared optical system
|
|
Field of View
|
5°\10°\20°\30°
(Electric diaphragm, software selection)
|
0.75°\1.5°\2.25°\ 3.0°
(Electric diaphragm, software selection)
|
2.5mrad \ 5°\10°
(Electric diaphragm, software selection)
|
|
Filters
|
1 filter holder (manual replacement)
|
|
Alignment
|
CCD image aiming (5°FOV) 5-inch LCD screen
|
|
Data Rate
|
·
1Hz(High precision mode)、10Hz、20Hz、50Hz(Quick measurement mode) (Signal modulation frequency 1KHz)
|
|
Output interface
|
RS-422 (Maximum transmission distance 200 meters)
|
|
Power Supply
|
220VAC/24VDC
|
|
Temperature
|
-40℃
~ +50
℃
|
|
Dimension
|
279(L)* 202(H)*274(D)---RLK601、RLK602、RLK602D
368(L)* 202(H)*274(D)---RLK603
|
|
Weight
|
8.0Kg(RLK601、RLK602、RLK602D)/10Kg(RLK603)
|
|
Software
|
RLK600Manager(V4.0) Special software for digital infrared radiometer
Three functions: measurement control, data processing and product calibration
|
|
Option
|
Tripod, laptop (common/reinforced), filter: 3.0-5.0um、 8-14 um or user specified
·
IRIG-B(DC) or IRIG-B(AC) time code signal input
|